Motor, Electric Motor, Asynchronous Motor manufacturer / supplier in China, offering Explosion Proof Motor Yb2-63, Repair or Remanufacture Rexroth Series Piston Pump Engine Parts A4vg28/40/56/71/90 Plunger Pump Hydraulic Pumpspare Parts, Vickers 20V14 Single Hydraulic Vane Pump Core Cartridge and so on.

(/ )

Supplier Homepage Product Others Explosion Proof Motor Yb2-63

Explosion Proof Motor Yb2-63

This product is currently unavailable, but you may contact the supplier directly, for further interest.
Basic Info
  • Model NO.: Yb2-63
  • Operating Speed: Constant Speed
  • Species: Y, Y2 Series Three-Phase
  • Casing Protection: Closed Type
  • Starting Mode: Direct on-line Starting
  • Brand: Timeway
  • Scope of The Center Height: H63~H355
  • Protection Class: IP55
  • Origin: China
  • Application: Industrial
  • Number of Stator: Three-Phase
  • Rotor Structure: Squirrel-Cage
  • Number of Poles: 2,4,6,8,10,12
  • Certification: ISO9001, CCC, CE
  • Work Mode: S1
  • Protect Feature: Explosion-Proof
  • Specification: ISO9001-2000 CCC
  • HS Code: 850152000
Product Description
General description
YB2 explosion-proof motor is in conformity with technical data of JB/T7565.1(Frame63-355), GB3836.1 and requirements of < Explosive Atmospheres Part 1: Equipment Protection by Flameproof Enclosures "d">. The explosion-proof marks are ExdI Mb. Exde IIAT4Gb, Exde IIBT4Gb. It is fit for the equipments down the coal mine well which has methane or coal dust and the place where has II types of A and B class T1-T4 combustibility air or explosion mixture by fume and air formation. It works as a general motive equipments.

Working condition
3.2.1 The environment air temperature varies with seasonal variation, does not exceed 35 (under coal mine) or the 40º C (factory), air minimum temperature is -15º C.
3.2.2 Elevation not more than 1, 000 meters
3.2.3 The maximal relative humidity of ambient air does not exceed 95% (while the temperature is 25º C) (down coal mine) or the maximal relative humidity of the wettest monthly averages is the monthly averages minimum temperature's turn not to overtop 25º C at the same time for 90% (the factory uses).
3.2.4 Fixed voltage: 220V, 380V, 660V, 220V/380V, 380V/660V.
3.2.5 Fixed frequency: 50Hz
3.2.6 The electric motor quota is the continuous quota taking that continuous duty type makes (S1) as criterion, allows full pressure to get it in gear.
3.2.7 The electric motor's insulation class is F level. The stator winding gets the temperature rise(Electric resistance method) examining according to 80K(2 pole and 4 pole of frame 315L, and frame 355 allowed to be examined according to 105K), bearing temperature does not exceed 95º C.